AZoM - The A to Z of Materials
 


 
Mid-Mountain Materials - A leading manufacturer of industrial textiles
Approved Professional Development Courses from Loughborough University
Dynamic Ceramic a UK based manufacturer and supplier of Ceramic Components. The UK's leading specialist producer of zirconia, alumina and other advanced ceramics.
Zwick Roell / Your Partner for Materials Testing
Oxford instruments - materials identification, OES and XRF

Thermo Finnigan LTQ-FT Mass Spectrometer


 
Classified Advert:
Thermo Finnigan LTQ-FT Mass Spectrometer
Company:
International Equipment Trading Ltd.
Location:
Vernon Hills, Illinois, USA
Web Site: Click here for more information
Details:

Thermo Finnigan LTQ-FT mass spectrometer- LC/MS/MS complete with Edwards E2M30 pumps, Pfeiffer Duo 25 pump, Pentium IV PC with Windows XP Professional, HP Laserjet Printer 2300d, Dell 19" LCD monitor, Xcalibur 2.0 software with license and manuals.

The Thermo Finnigan LTQ FT hybrid linear ion trap - Fourier Transform ICR mass spectrometer provides high resolution, accurate mass determinations, and MS-n. The FT Ion Cyclotron Resonance analyzer has an actively shielded 7 Tesla superconducting magnet. Ions trapped in the ICR cell are excited by applying a SWIFT (Stored Waveform Inverse Fourier Transform) waveform. Mass range is 50 to 2000 in FT mode. The FT resolution is user selectable from 12,500 (FWHM) up to a maximium mass resolution of 500,000 at m/z 400.

It is capable of simutaneous high resolution, mass accuracy, and sensitivity over one mass decade (e.g. m/z 200 - m/z 2000). It has a fast data acquisition rate (1 second repetition rate) with very high resolution (100,000 at m/z 400). The mass accuracy is better than 2 ppm with external calibration. Sensitivity is sub fmol on-column in LC/MS. It is cabable of simultaeous full scan FT MS, data dependent zoom scan, and MS/MS scans. It is equipped with several nanoESI sources (including static, dynamic, and packed tip) with a Pulnix video camera and has the standard Finnigan IonMax API source with the ESI attachment. The ICR cell has an Electron Capture Dissociation (ECD) emitter cathode attached to the back of the cell. The ECD method of fragmentation produces c and z ions. This method preserves co- and post-translational modifications (PTMs) such as phosporalation, O- and N-linked glycosalation and sulfation. The LTQ also has Wide Band Activation which allows the simultaneous fragmentation of a parent ion and its corresponding water loss peak by resonance excitation.

SPECIFICATIONS

  • Resolution to 100000
  • Mass Accuracy 1-2 ppm with internal standard
  • Mass Accuracy <1 ppm Sim mode
  • Electron Capture Dissociation Capable

APPLICATIONS

  • High accuracy molecular weight determination
  • Top down protein microsequencing and identification
  • Bottom up protein microsequencing and identification

Please contact us for complete LTQ-FT system, warranty and service contract details.

Close Date: 9-May-2010
Contact Email: info@ietltd.com
Contact Name and Phone: Sales
  Click here for more information
 
CILAS state of the art laser particle size analyzers
Materials Science books by Elsevier
University of Surrey-Short Courses and MSc in Materials science
X-Ray diffractometers from Shimadzu

 

FIBERStone - high purity, refractory ceramic
version 2.0 - AZoM™ - The A to Z of Materials and AZojomo - The "AZo Journal of Materials Online"...AZoM™.com Pty.Ltd Copyright © 2000-2009