Fischer FMP30-40 Coating Thickness Measurement Instrument

The Fischer FMP30-40 series is even more versatile than the standard models FMP10-20. These instruments integrate additional features such as more memory for numerous applications as well as extensive statistical and graphical evaluations. Tolerance limits can be entered into the calibratable applications and the production process can be analyzed statistically. The default mode can be switched to matrix mode for connected multipoint measurements. These are only a few of the many features described below.

Depending on your measuring application, you can make precise coating thickness measurements according to the magnetic induction method (DELTASCOPE® FMP30), the eddy current method (ISOSCOPE® FMP30) or according to both methods combined in one instrument (DUALSCOPE® FMP40). You will be able to measure most standard or special applications with a wide assortment of Fischer plug-in type probes.

Characteristic Features of the FMP30-40 Series: (features additional to those of the FMP10-20 series)

  • Automatic base material recognition (FMP40).
  • Memory for up to 20,000 readings
  • Up to 100 calibratable applications
  • Capability of allocating readings into up to 4,000 blocks
  • Date and time stamp for blocks
  • Statistics display of common characteristic values in the block and fi nal results. Output of characteristic variance-analytical values
  • Graphical measurement display as a histogram with a Gaussian plot
  • Capability of entering process tolerance limits and computation of the associated process capability indices cp and cpk
  • Audible and visual warning when tolerance limits are exceeded
  • Free-running display with additional presentation of the reading as an analog bar between the tolerance limits
  • External key-triggered measurement acquisition, e.g., in hollow cylinders with small diameters
  • Option to calibrate through an unknown coating (with magnetic induction method only)
  • Capability to enable matrix measurement mode for connected multi-point measurements
  • Capability of averaging measurement data: Only the mean value of several readings will be stored
  • Measurement acquisition through area measurement possible: Only the single readings until probe lift-off are captured and averaged
  • Capability to measure continuously with the probe placed on the specimen
  • Outlier rejection for the automatic elimination of erroneous measurements
  • Correction of any stored reading
  • Application linking mode: Ability for common normalization/calibration of applications
  • Designations for applications through the optional PC program MP-Name
  • USB port to a printer
  • Battery and line power operation