5-Point Traceable Calibration High Stable Wet/Dry Differential Pressure Transducers

The wet/dry transducers from OMEGA are rugged stainless steel transducers that are suitable for automotive, industrial, or aerospace applications where only a single side of the transducer is exposed to wet media. These transducers provide the excellent performance characteristics of the Micro-Machined Silicon Series Transducers at a lower price than the wet/wet models.

They can be used in filter monitoring, factory, test benches, air flow or pneumatic air, pitot tubes, air speed and other aerospace or industrial application requiring a very robust wet/dry transducer. The solid state silicon core offers long, reliable service life with superior long term stability.

  • Five-point traceable calibration
  • 316 L SS wetted parts on wet side– clean dry gases on dry side
  • Wide compensated temperature range
  • Low drift, high stability
  • Welded stainless steel construction
  • Premium temperature performance
  • Durable, one million cycle life
  • Precision micro-machined silicon core
  • Customized specifications available
  • Ruggedized with secondary containment
  • Also available with M12 connector (PX459)

Common Specifications

The common specifications of the wet/dry transducers are as follows:

  • Minimum resistance between transducer body and any wire: 100 MΩ
  • Long term stability (1-year): ±0.1% FS typical
  • Accuracy: 0.08% BSL linearity, repeatability and hysteresis combined
  • Compensated temperature range:
    • 10 in H2O to 5 psi: -17 to 85 °C (1 to 185 °F)
    • 15 to 1000 psi: -29 to 85 °C (-20 to 185 °F)
  • Pressure cycles: 1 million minimum
  • Operating temperature:
    • mV/V and 5 to 10 Vdc output: -45 to 121 °C (-49 to 250 °F)
    • mA output: -45 to 115 °C (-49 to 239 °F)
  • Response time: <1 ms
  • Thermal accuracy:
    % Span shift over compensated temperature range
    • 10 in H2O to 5 psi: Zero - ±1.00%; Span - ±1.00%
    • 15 to 1000 psi: Zero - ±0.50%; Span - ±0.50%
  • Bandwidth: DC to 1 kHz typical
  • Media compatibility:
    • Positive side: All fluids and gases compatible with 316L SS
    • Negative side: Dry, clean, non-ionic gases
  • Shock: 50 g, 11 ms, half-sine, vertical and horizontal axis
  • Pressure ports: ¼NPT male
  • CE complient: Meets EN61326-1: 2006 for industrial locations
  • Vibration: 5-2000-5 Hz 30 minute cycle, curve L Mil-Spec 810 figure 514-2-2, horizontal and vertical axis
  • Proof pressure (differential):
    • 10 in H2O range = 10 times range
    • 1 psi range = 6 times range
    • 2.5 to 750 psi ranges = 4 times range
    • 1000 psi range = 3 times range
  • Line/static pressure: 500 psi max applied to both sides simultaneously
  • Hi side containment pressure (differential):
    • Ranges 10 in H2O to 5 psi: to 1000 psi
    • Ranges 15 to 1000 psi: to 3000 psi
  • Weight: 200 g (7 oz) max
  • Electrical terminations:
    • PX409: 2 m (6') cable
    • PX409C: 2 m (6') cable with ½ NPT conduit thread
    • PX419: Mini-DIN (includes mating connector)
    • PX429: Twist-lock, mating connector (sold separately)
    • PX459: M12 connector, mating connector (sold separately)
    • Mating connector for PX429: PT06F10-6S

Uni-Directional mV/V Specifications

The uni-directional mV/V specifications of the wet/dry transducers are as follows:

  • Current draw: 5 mA @ 10 Vdc
  • Output: 10 mV/V ratiometric
  • Span setting:
    • Ranges ≤ 2.5 psi: ±1% typ (2% maximum)
    • Ranges > 2.5 psi: ±0.5% typ (1% maximum)
  • Supply voltage: 5 to 10 Vdc
  • Zero balance:
    • Ranges ≤ 2.5 psi: ±1% typ (2% maximum)
    • Ranges > 2.5 psi: ±0.5% typ (1% maximum)
  • Input impedance: 1000 to 5000 Ω
  • Output impedance: 5000 Ω ±10% typical

Uni-Directional Voltage Output Specifications

The uni-directional voltage output specifications of the wet/dry transducers are as follows:

  • Current draw: 10 mA max
  • Output impedance: 100 Ω
  • Output voltage/supply voltage: 0 to 5 Vdc/ 10 to 30 Vdc; 0 to 10 Vdc/15 to 30 Vdc (change "5V" to "10V" in model number)
  • Zero balance:
    • Ranges > 2.5 psi: ±0.5% typ (1% maximum)
    • Ranges ≤ 2.5 psi: ±1% typ (2% maximum)
  • Maximum current output: 2 mA (= 2500 Ω min load resistance)
  • Span setting:
    • Ranges > 2.5 psi: ±0.5% typ (1% maximum)
    • Ranges ≤ 2.5 psi: ±1% typ (2% maximum)

Uni-Directional mA Specifications

The uni-directional mA specifications of the wet/dry transducers are as follows:

  • Supply voltage: 9 to 30 Vdc; [9 to 20 Vdc above 105 °C (229 °F)]
  • Output: 4 to 20 mA
  • Zero balance:
    • Ranges > 2.5 psi: ±0.5% typ (1% maximum)
    • Ranges ≤ 2.5 psi: ±1% typ (2% maximum)
  • Maximum loop resistance: (Vs-9) x 50 Ω
  • Span setting:
    • Ranges > 2.5 psi: ±0.5% typ (1% maximum)
    • Ranges ≤ 2.5 psi: ±1% typ (2% maximum)

Four Termination Styles

The following are the four termination styles available with wet/dry transducers:

  • PX409 = 2 m (6ft) cable
  • PX419 = mini-DIN connector
  • PX429 = Twist-lock connector
  • PX459 = M12 connector

Other Equipment by this Supplier

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.