In response to standardization requirements of the oil and gas industry, Victrex Polymer Solutions contracted MERL to perform an investigation to evaluate the compliance of VICTREX® PEEK to the NORSOK M-710 Standard for sour (H2S) aging at 1,450 psi (10 MPa) and test temperatures of 175°C (347°F), 195°C (383°F) and 210°C (410°F) for up to five weeks. Results showed no measurable chemical deterioration for the VICTREX PEEK 450G in this time period of testing.

In response to standardization requirements of the oil and gas industry, Victrex requested an evaluation of the extent to which VICTREX® PEEK complies with the NORSOK M-710 standard for sour H2S aging at high pressure and temperature for up to five weeks. Results, as seen in the attached photo, exceeded the standard and showed no measurable chemical deterioration for the VICTREX PEEK sample.

This lack of any change, a testament to the H2S resistance of VICTREX PEEK 450G, prohibited any extrapolation or interpolation of results for predictive modelling. Recognizing the data generated may not go far enough to offer the level of confidence in performance that is required, Victrex has undertaken further testing to understand and model how VICTREX PEEK polymers will perform in even the most demanding oil and gas environments.

To date, VICTREX PEEK polymer has been tested in three-phase sour environments where the gas phase is 100% H2S corresponding to more than 1% at  30,000 psi (207 MPa) and at temperatures of 220°C (428°F). Even under such unforgiving conditions, ten times the NORSOK standards, the mechanical properties of VICTREX PEEK 450G are fully retained in the aqueous and hydrocarbon phases. This testing is the beginning of a series of additional fluid analysis testing that will be taking place in the coming months in response to direct requests by industry material specifiers and end users to ensure operations are safe and efficient for long service life.

Senior Technical Advisor for Baker Hughes Completions and Productions, Jim Goodson, confirms:

“Victrex provides the industry an excellent service with quality data both through the standardized testing practices and their own extended product analysis efforts. When material manufacturers or intermediate processors utilize those same standards and techniques to produce data on their own materials, we have more confidence that the data produced is consistent and accurate saving us time and effort in evaluation of those materials.”

To further demonstrate the outstanding performance of VICTREX PEEK polymers  and benefit customers in the energy sector; Victrex Technical Manager Geoff Small, is leading a team to test and predictively model VICTREX PEEK polymers in even more aggressive environments. The advanced testing of higher H2S concentrations and additional oil and gas fluids testing is highlighted in a new whitepaper available for download at www.victrexenergy.com.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Victrex plc.. (2019, February 08). Victrex Announce Compliance of PEEK with NORSOK M-710 Sour Aging Standard. AZoM. Retrieved on April 20, 2024 from https://www.azom.com/news.aspx?newsID=38994.

  • MLA

    Victrex plc.. "Victrex Announce Compliance of PEEK with NORSOK M-710 Sour Aging Standard". AZoM. 20 April 2024. <https://www.azom.com/news.aspx?newsID=38994>.

  • Chicago

    Victrex plc.. "Victrex Announce Compliance of PEEK with NORSOK M-710 Sour Aging Standard". AZoM. https://www.azom.com/news.aspx?newsID=38994. (accessed April 20, 2024).

  • Harvard

    Victrex plc.. 2019. Victrex Announce Compliance of PEEK with NORSOK M-710 Sour Aging Standard. AZoM, viewed 20 April 2024, https://www.azom.com/news.aspx?newsID=38994.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this news story?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.