Turbo Blower Unit - TB

Designed exclusively for medium and small volume flows, the frequency-controlled TB Turbo blowers from AERZEN is capable of delivering maximum energy efficiency. Their state-of-the-art compressor technology enables them to be perfect additions to the AERZEN portfolio: now the right machine is available for every level of volume flow.

The Benefits of Aerzen Turbo TB at a Glance

  • Ready-to-run deliverables
  • Direct measurement of air volume
  • Advanced controls
  • Highest energy efficiency, up to 30% savings
  • Permanent magnet synchronous motor
  • Air foil bearings for extreme demands
  • Innovative frequency inverter, active surge protection (high rise to surge)

Technical Data

. .
Type of technology: Turbo blowers
Design: Positive pressure
Volume flow: 300 to 6,000 m3/h
Medium: Air, Neutral gases
Conveying/compression: Oil-free
Positive pressure: Max. 1,000 mbar

Properties

AERZEN has been manufacturing Turbo blowers ever since 1911. In the decades since then, the company succeeded in reaching new heights in refining the technology of these units. New standards have been established with the expertise that has been achieved. These standards have been reflected in the components, the performance characteristics, in all the details of the latest Turbo. Customers can find out for themselves: the Turbo Generation 5.

100% Turbo

  • From 300 m3/h to 6000 m3/h
  • For mid and high airflows
  • Variable frequency control
  • 100% oil-free

Efficient Peak Values

  • Up to 80% efficiency
  • Up to 30% energy savings
  • Minimal maintenance costs
  • Highly efficient individual components
  • Control range from 40-100%

Power Motor

  • PMS – Permanent Magnet Synchronous Motor
  • Extraordinary performance and response times
  • Highly efficient during partial load operation
  • No need for additional magnetization energy
  • Stainless steel impeller

Air Foil Bearings for Extreme Demands

  • No components that would be subject to wear
  • Absorbs even extreme pressure fluctuations
  • Contact-free and vibration-free operation
  • Development from the aerospace industry
  • 100% maintenance-free
  • Low energy idle mode

Applications

Precise Load Cycle Calibration: For A New Level of Efficiency in Aeration Tanks

When users realize that energy consumption in conventional waste water treatment plants can be up to 80% of total costs, then the impact becomes clear: every single percentage point in savings counts, both in terms of the environment and cost. The performance values for the Aerzen Turbo Generation 5 refer to maximum effectiveness in waste water tanks. In numbers: energy savings of up to 30%. And up to 80% operational efficiency. That is really amazing – practically revolutionary! AERZEN believes that this is just the most responsible way for managing resources in waste water treatment plants.