Photobiological Safety Spectroradiometer - IDR300-PSL

Lamp and luminaire manufacturers as well as test and certification companies can now assess photobiological safety of lamps and lamp systems faster, easier and with higher accuracy than ever before.

Photobiological safety testing to comply with international standards requires a measurement capability spanning the 200-3000 nm spectral wide range in consideration to six hazards to the eye and skin. The IDR300-PSL spectroradiometer from Bentham facilitates the required series of spectral radiance and spectral irradiance measurements, while ensuring full compliance with the suggested measurement instrumentation. The full hardware automation and complete measurement guidance, calculation and report generation enables the IDR300-PSL to be at the center of photobiological safety testing in accreditation and the light source manufacturer's laboratories all over the world.

Core Benefits

  • Assess all product types, from UV through to IR
  • Quality of measurements guaranteed through NMI calibration standards traceable to PTB
  • Includes full measurement guidance, calculation and report generation
  • Fully compliant to instrumentation recommendation of international standards

Features

  • Motorized slits to adjust instrument bandwidth throughout scan range
  • Double monochromator-based spectroradiometer (200-3000 nm)
  • Radiance: Direct view telescope permitting measurement from 200 mm to 10 m in key 1.7, 5 and 11 mrad FOVs. Connected to IDR300 with 1 m long quartz fiber bundle
  • Irradiance: Precision transmission diffuser connected to IDR300 with 1 m long quartz fiber bundle
  • Quartz halogen, incorporating sphere-based radiance standard, provided with calibration traceable to PTB, Germany
  • Quartz halogen and deuterium irradiance standards, provided with calibration traceable to PTB, Germany
  • Benwin+ Windows spectroradiometer control
  • Beam profiler employed to determine (apparent) source size and location
  • Photometric detector with virtual luxmeter operation for determining illuminance (500 lx, dthr)
  • PSL Wizard measurement guidance, calculation and report generation application

Applications

Accurate photobiological safety evaluation to:

  • EU Low Voltage Directive, 2014/35/EU
  • IEC 62471:2006, Photobiological safety of lamps and lamp systems
  • EN 62471:2008, Photobiological safety of lamps and lamp systems
  • IEC TR 62471-2:2009, Photobiological safety of lamps and lamp systems - Part 2
  • JIS C 7550:2011, Photobiological safety of lamps and lamp systems
  • EN 62471-5:2015, Photobiological safety of lamps and lamp systems - Part 5: Image projectors
  • IEC 62471-5:2015, Photobiological safety of lamps and lamp systems - Part 5: Image projectors

Reported Parameters

  • Labeling requirements
  • (Apparent) Source size and location
  • Risk group classification
  • Spatially averaged spectral radiance
  • Spectral irradiance
  • Threshold distance, dthr
  • Threshold illuminance, Ethr