The AII-3000 range or Palm O2 analyzers from Analytical Industries are a convenient means to monitor oxygen levels in welding gases. These inexpensive gas analyzers also measure and display the oxygen concentration in compressed breathing air tanks intended for personnel safety and scuba diving, O2 deficiency in confined spaces, and also for verifying the O2 levels before welding.

These monitors are equipped with similar electrochemical galvanic fuel cell oxygen sensors that are largely used for the measurement of concentrations from 0% to 100% O2 in gas streams:

  • Long sensor life of up to 60 months (AII-3000)
  • Integrated or remote sensors
  • 0%–100% O2 measurement range
  • Up to 13,000 hours of battery life for continuous use (Palm O2)
  • Fast T90 response time of <10 seconds

Nitrox Analysers for Welding

Nitrox Analyzers for Welding

Technical Specifications

  AII-3000 Palm O2 Palm CO Analyzer
Measurement range 0-100% oxygen 0-25 ppm CO
Accuracy < ±2% of FS range under constant conditions < ±2 ppm under constant conditions
Response time T90 < 10 seconds T90 < 30 seconds
Sensitivity (LDL) 0.50% 0.5 ppm CO
Linearity ±1% under constant conditions
Sensor model AII-11-60 (remote sensor)
AII-11-60-HC
AII-11-75-PO2
AII-11-75-PO2-D (for diving)
OSV-22-AF
Sensor life at 25 °C (77 °F) and 1 atmosphere 60 months in air 5 °C (77 °F) and 1 atmosphere 32 months in air 5 °C (77 °F) and 1 atmosphere 24 months in air 5 °C (77 °F) at 1 atmosphere
Calibration interval Prior to use and after 8 hours operation Certified span gas mixture of CO concentrations between 10-20 ppm with balance air.
Inlet pressure Ambient or 0.34-2 barg (5-30 psig) for flow through connector 800 1200 mbara (11.6-17.4 psig)
Flow rate (constant) 0.2-10 Nl/min (0.4-20 SCFH)
Gas connections 1x16 mm thread
1/4" tube for remote sensors
See accessories for additional connectors
Supplied with Dome adapter (A-3388) with optional BC adapter (A-3671)
Display 3½ digit backlit LCD 7 x 3.5 cm (2.75 x 1.375"); resolution 0.1 3 digit LCD 2.8 x 1.6 cm (1.1 x 0.625"); resolution 0.1 2 digit LCD 2.8 x 1.6 cm (1.1 x 0.625"); resolution 1 ppm CO
Dimensions 9.1 x 14.9 x 4 cm (3.6 x 5.9 x 1.6") 6.9 x 10.4 x 3.4 cm (2.72" x 4.1" x 1.35")
Weight 280 g (10 oz) 196 g (7 oz)
Compensation Temperature compensated NA
Alarms User adjustable HI and LO alarms (AII-3000 M and MHC only)
Storage temperature -20 °C to +60 °C (-4 °F to 140 °F) on intermittent basis 3 °C to 35 °C (37.4 °F to 95 °F)
Operating temperature 5 to 45 °C (41 °F to 113 °F) 0 °C to 50 °C (32 °F to 122 °F)
Power 2 AA alkaline batteries
Battery Life Up to 1200 hrs Up to 1300 hrs Up to 450 hrs of continual use
Humidity Non-condensing 0-95% RH
Warm up time None 60 Seconds
Approvals ISO 9001:2000, MDD 93/42/Annex II, ISO 13485:2003 None