AZoM - The A to Z of Materials


 

If you'd like us to help you source a Quotation for this product, please complete the inquiry form with details of your area of interest and we will pass on your inquiry to the relevant person or department within the related company or organisation.

Once submitted, we will try and place you in contact with a suitable supplier within 48 hours.

Why do we go to all this effort on your behalf?

Simple -

What you should know

Well, there's a few conditions that apply;

  • You agree NOT to pay us for this service.
  • We can only process requests where the email address matches the company name, e.g., yourname@yourcompany.com - We cannot respond to free email accounts such as hotmail)
  • You accept that you may be contacted by the supplier in response to your enquiry either by email, phone or mail.
  • You accept that the operators of www.AZoM.com cannot guarantee the suitability of any materials or services you may purchase from a supplier we've contacted on your behalf. You have to check that out with the supplier.
  • You're comfortable with supplying us with relevant information, for example, who you are and where you are based, what you want, how many you want, any delivery deadlines, restrictions on the location of the supplier, any price targets etc etc.
  • We will safeguard your privacy and only pass on the details contained in your email to the relevant supplier or suppliers if you've asked for that.
  • We can't guarantee that the supplier will respond and if they don't, you agree you won't get angry with us.
  • We promise we won't subject you to any follow up spam mail.
  • If you don't receive a response within 10 working days please send us a follow up enquiry and we'll try and help further.
 
 
Saving...
Thank you. Your Inquiry has been Successfully Received, and will be processed by the AZoM RFQ Team.
Aculon-Unique Molecular-Scale Surface and Interfacial Coatings
Handheld Thermo Scientific Niton XRF analyzers are engineered for portable elemental analysis
Malvern Morphologi G3 particle characterization system
The New D8 ADVANCE – the 1st truly all-purpose Diffraction Solution for X-ray Powder Diffraction
High precision machining of hard materials, Insaco
Princeton Instruments- Imaging & Spectroscopy Cameras
ADMET universal materials testing machines
Composites Europe - Trade Fair and Forum for Composites, Technology and Applications
Titanium Dioxide Dispersion Monitoring for Pigment Applications Usingthe Mastersizer 2000 From Malvern Instruments

Titanium Dioxide Dispersion Monitoring for Pigment Applications Using the Mastersizer 2000 From Malvern Instruments

AZoM - The A to Z of Materials, Metals, ceramics, composites and polymers : Malven Logo

Topics Covered

Background

The Importance of Pigment Particle Size

The Effect of Over-Sized Particles

Pigment Particle Size and Light Scattering Strength

Commercial Aspects of Optimising Particle Size

Dispersion Monitoring Using The Mastersizer 2000

Primary Measurements

Aggregate Detection

Conclusions

Background

Titanium Dioxide is the world’s most widely utilised white pigment. It’s high refractive index, ease of dispensability and photochemical stability are unique. For this reason it is used to impart opacity and whiteness to an enormous variety of products including paints, plastics, inks, paper, cosmetics, foodstuffs and pharmaceuticals.

The Importance of Pigment Particle Size

One of the most important factors in determining the effectiveness of titanium dioxide pigments is the pigment particle size. The particle size controls several important properties including:

·         Colour

·         Opacity (scattering strength)

·         Gloss

·         Tinting strength

·         Viscosity

·         Sedimentation rate

The Effect of Over-Sized Particles

The presence of over-sized particles can significantly impair the performance of the final pigment dispersion. It is therefore necessary to monitor the dispersion characteristics during production and use of the titanium dioxide in order to obtain optimal pigment performance.

Pigment Particle Size and Light Scattering Strength

The particle size of titanium dioxide pigments must be carefully controlled in order to maximise the light scattering from the pigment suspension. The particle size (D) at which the maximum scattering power is seen for a high refractive index pigment is given by Weber’s formula:

                1

where λ is the wavelength of the incident light, n1 is the refractive index of the pigment and n2 the refractive index of the continuous phase. Table 1 shows the optimum size required for rutile titanium dioxide in water in order to see maximum scattering for blue, green and red light.

Table 1. Optimal particle size for rutile in water in order to see maximum scattering of blue, green and red light.

Wavelength

Size (µm)

Blue (430nm)

0.20

Green (550nm)

0.26

Red (660nm)

0.31

Commercial Aspects of Optimising Particle Size

A particle size of around 0.25 microns yields the highest scattering efficiency across the entire visible spectrum for rutile titanium dioxide. For anatase titanium dioxide, the ideal particle size is around 0.3 microns. Milling to below this size significantly reduces the pigment scattering power and increases the manufacturer’s costs, both in terms of milling time and the concentration of pigment required to give a certain tinting strength. Conversely, the presence of large particles or aggregates yields a yellow undertone due to poor scattering efficiency at the blue end of the visible spectrum. The presence of aggregates also reduces the tinting strength, gloss and opacity of the pigment suspension, as well as increasing the viscosity due to particle interactions. It is therefore important to carefully control the pigment particle size and eliminate any aggregates during milling.

Dispersion Monitoring Using The Mastersizer 2000

Primary Measurements

The particle size of a titanium dioxide suspension was determined using the Malvern Mastersizer 2000. Measurements were first carried out in deionised water. Figure 1 shows the size distribution reported by the instrument. As can be seen, the "primary" particle size for this titanium dioxide sample is close to that required in order to see the maximum amount of scattering from the particles. Five individual results are overplotted in figure 1.This shows the repeatability of the results obtained using the Malvern Mastersizer 2000.

AZoM - Metals, Ceramics, Polymer and Composites: Primary particle size distribution for the titanium dioxide slurry. Determined using a Malvern Mastersizer 2000

Figure 1. Primary particle size distribution for the titanium dioxide slurry.

Aggregate Detection

The ability to detect aggregates as well as "primary" particles is of paramount importance to the paint manufacturer. The titanium dioxide slurry was therefore destabilised by adding an excess of a highly charged electrolyte to the Malvern Mastersizer 2000 sample dispersion unit. This reduces the charge on the particles, leading to particle aggregation. The particle size reported by the instrument for the unstable slurry is shown in figure 2. As can be seen, the instrument is able to detect both the primary particles and the large aggregates formed during destabilisation of the slurry. Figure 3 shows the change in the volume mean diameter (D[4,3]) reported by the Malvern Mastersizer as the aggregation process is continued. The instrument successfully tracks the growth of the aggregates until an equilibrium particle size is attained.

AZoM - Metals, Ceramics, Polymer and Composites: Particle size distributions reported during the destabilisation of the titanium dioxide slurry, Determined using a Malvern Mastersizer 2000

Figure 2. Particle size distributions reported during the destabilisation of the titanium dioxide slurry.

AZoM - Metals, Ceramics, Polymer and Composites : Change observed in the volume average particle size (D[4,3]) during aggregation of the titanium dioxide slurry. Determined using a Malvern Mastersizer 2000

Figure 3. Change observed in the volume average particle size (D[4,3]) during aggregation of the titanium dioxide slurry.

Conclusions

The ability of the Malvern Mastersizer 2000 to measure the particle size of titanium dioxide slurries has been demonstrated. The instrument provides an ideal method for monitoring the state of dispersion of titanium dioxide paints and pigments, an important factor in controlling the performance of the final product.

 

Date Added: Apr 20, 2005


 

 

Email / Share
 
 
CILAS state of the art laser particle size analyzers
Particle Sizers from Brookhaven Instruments
Bruker Handheld XRF Spectrometers
Materials Science & Technology 2010 Conference & Exhibition
Metals and Materials for Research - Goodfellow
Aluminium 2010 - No.1 Aluminium event worldwide
NanoTest™, the complete nanomechanical testing center
Shimadzu - Energy Dispersive X-Ray Analysis Instruments
Dynamic Ceramic a UK based manufacturer and supplier of Ceramic Components. The UK's leading specialist producer of zirconia, alumina and other advanced ceramics.

 

Picosun SUNALE P-Series Atomic Layer Deposition (ALD) Reactors
AZoM™ - The A to Z of Materials and AZojomo - The "AZo Journal of Materials Online"...AZoM™.com Pty.Ltd Copyright © 2000-2010