X-ray fluorescence (XRF) spectroscopy is widely used in chemical analysis. It detects major and trace elements non-destructively at concentrations ranging from 100 % to sub-PPM. This applies to a wide spectrum of elements, typically from beryllium (Be) to uranium (U). However, it is not without flaws.

Image Credit: Adwo/Shutterstock.com
Matrix effects, for example, present a significant challenge to accuracy. Elemental differences in the sample cause these effects. They can interfere with X-ray absorption and fluorescence emission, reducing the accuracy of the results. Fortunately, there are tried-and-true ways for overcoming matrix effects.
1. Prioritize Proper Sample Preparation
Accurate XRF analysis begins with precise sample preparation. A homogeneous and representative sample, free of contaminants, is required to reduce matrix effects.
This often involves crushing and pulverizing the sample into fine dust, ensuring a uniform distribution of materials inside the sample. Following that, the material must be precisely weighed and mixed with flux.
One of the most effective strategies for mitigating matrix effects is fusion, specifically lithium borate fusion. This process converts a sample into a homogeneous glass bead, removing mineral features that may interfere with analysis.
2. Utilize a Hydraulic Press for Sample Consistency
Instead of fusion with lithium borate, consider compacting your samples into discs or pellets with a hydraulic press to reduce matrix effects.
This procedure ensures that the sample's surface is as uniform and representative as possible, minimizing surface variances that can affect emission spectra. Consistency in the sample's flatness and density is critical for reducing localized heterogeneities, which are a typical source of error in the matrix.
3. Leverage Electric Fusion Machines for Homogeneous Samples
Electric fusion machines are extremely useful tools for reducing matrix effects in XRF spectrometry. These devices employ resistance heaters to fuse samples with a fluxing solution, resulting in uniform discs or beads.
This method reduces irregularities within the sample, ensuring that measurements accurately reflect the sample's composition without interference from matrix effects.
4. Implement Matrix Correction Techniques
Even with meticulous sample preparation and processing, matrix effects can still emerge because other constituents in the sample influence the measured X-ray counts. Matrix correction techniques are critical for addressing this issue.
These include foundational, empirical, or regression methods that account for absorption and enhancement effects, ensuring that XRF results are correct and reflect the sample's true composition.
Do Not Let Matrix Effects Impact Your XRF Spectrometry
These strategies: proper sample preparation, using a hydraulic press, using electric fusion machines, and applying matrix correction techniques, can considerably reduce matrix effects in XRF spectrometry.
These approaches are critical for generating accurate and consistent analytical results, allowing you to maintain the highest standards in your XRF analyses.
Improve your XRF findings with XRF Scientific's premium solutions. The company’s high-performance hydraulic presses produce homogeneous sample pellets while reducing surface irregularities.
XRF Scientific’s electric fusion machines, which use exact fusing to make absolutely homogeneous glass beads, can successfully eliminate matrix effects. Invest in the company’s lithium borate fluxes to ensure constant and accurate XRF analyses. XRF Scientific also has XRF analysis products and publications that go into greater detail about XRF spectrometers.