Leak Detection and Repair (LDAR): A Comprehensive Introduction

Implementation of an effective Leak Detection and Repair (LDAR) program allows facilities to control emissions that may stem from equipment leaks.

Leak Detection and Repair (LDAR): A Comprehensive Introduction

Image Credit: Thermo Fisher Scientific – Environmental and Process Monitoring Instruments

The EPA defines LDAR as: “…a work practice designed to identify leaking equipment so that emissions can be reduced through repairs. A component that is subject to LDAR requirements must be monitored at specified, regular intervals to determine whether or not it is leaking. Any leaking component must then be repaired or replaced within a specified time frame.”

A Leak Detection and Repair (LDAR) program following best practices will be comprised of at least six phases.

1. What is LDAR.mp4

A facility should complete these phases on an ongoing basis, though the frequency and timing of each individual phase will vary depending on components in use, national or regional regulatory requirements, changes to equipment, and a range of other factors.

This article outlines the six phases of a successful LDAR program.

1. Identify Components

Every regulated component should be physically tagged with a unique ID number. This number should be recorded on a Piping and Instrumentation Diagram (P&I Diagram), along with details of any exempt components.

An equipment log or site plot plan must also be updated after any component changes. Facilities should have an appropriate procedure in place to update records where new equipment is installed, components are replaced, or specific parts are retired.

2. Define Potential Leaks

Leak Detection and Repair (LDAR): A Comprehensive Introduction

Image Credit: Thermo Fisher Scientific – Environmental and Process Monitoring Instruments

The lowest leak definition should be used in facilities where there are multiple regulations or components. This is considered to be the best practice, simplifying monitoring while reducing any potential for confusion.

This approach will also ensure a sufficient margin of safety for workers monitoring components and those working closest to any potential emissions.

Should contractors or workers be confused over which regulations apply, and utilize an incorrect leak definition for a specific component, leaks could persist and fail to be reported for repairs.

It is recommended that facilities check with current regulations to ensure that the correct leak definitions are being used.

3. Monitor Components

Leak Detection and Repair (LDAR): A Comprehensive Introduction

Image Credit: Thermo Fisher Scientific – Environmental and Process Monitoring Instruments

The use of an electronic and automatic data logger will not only save time but will also improve accuracy and ensure that an appropriate audit record is provided.

An LDAR program should be periodically audited to ensure that all components are being monitored.

This approach will also ensure that appropriate procedures are properly followed and that all necessary records are maintained.

Regular monitoring and quality checks of LDAR data are essential if a program is to continue to provide complete, accurate, and consistent results.

2. Automatic Calibration Advantages.mp4

In some instances, inspectors have exposed workers who seemed to cut corners on monitoring procedures.

For example, if records show a worker claiming to monitor around 1,000 components each hour, therefore taking under 5 seconds to check each component, then an investigation should be conducted.

Similarly, failing to check all components or moving too fast along a monitoring route will result in data that is unreliable or, at worst, worthless.

4. Repair Components

Leak Detection and Repair (LDAR): A Comprehensive Introduction

Image Credit: Thermo Fisher Scientific – Environmental and Process Monitoring Instruments

Facilities should develop an appropriate protocol and timetable for the repair of components. Ideally, a repair should be attempted as soon as possible, following the detection of a leak.

The installation of ‘leakless’ valves and ‘sealless’ components may help reduce future fugitive emissions, reducing the need for ongoing repairs. When components are repaired, it is prudent to increase the frequency at which they are monitored in order to confirm that the repair was successful and that the leak has been stopped.

5. Keep Consistent Records

Leak Detection and Repair (LDAR): A Comprehensive Introduction

Image Credit: Thermo Fisher Scientific – Environmental and Process Monitoring Instruments

Internal and third-party audits of LDAR records should be completed on a regular basis. This will help ensure that workers are properly monitoring all regulated components.

The use of databases and electronic monitoring will improve the quality of audits and maintenance of records without the need to manually sift through paperwork.

A robust auditing protocol will also include regular inquiries around new or revised regulatory requirements.

Overall, greater problems will arise should leaks not be repaired and reported as repaired in a timely manner or where these are incorrectly recorded on a delay of repair list.

6. Continuous Improvement

Regularly reviewing and updating records and written protocols are essential in the maintenance of an effective LDAR program.

This process should start with an audit of identified components, and this audit should be compared with current P&I diagrams and any alterations to components or equipment. Protocols for a written LDAR program should be reviewed and updated, and monitoring data should be audited.

New portable detecting instruments should be purchased as appropriate, and it is recommended to use calibration devices that can automatically calibrate multiple detecting instruments. An appropriate training program should also be in place for all workers or contractors.

It is important to maintain regular contact with regulatory agencies or industry associations in order to keep up to date on existing or new compliance requirements that may require internal leak definitions to be adjusted.

The Delay of Repair list and repair records should be reviewed regularly, and an inventory should be maintained of all portable detecting instruments and calibrators. These instruments should also be regularly checked to confirm they are functioning properly, with preventative maintenance or external servicing implemented as appropriate.

Logo

This information has been sourced, reviewed and adapted from materials provided by Thermo Fisher Scientific – Environmental and Process Monitoring Instruments.

For more information on this source, please visit Thermo Fisher Scientific – Environmental and Process Monitoring Instruments.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Thermo Fisher Scientific – Environmental and Process Monitoring Instruments. (2023, May 26). Leak Detection and Repair (LDAR): A Comprehensive Introduction. AZoM. Retrieved on April 28, 2024 from https://www.azom.com/article.aspx?ArticleID=20136.

  • MLA

    Thermo Fisher Scientific – Environmental and Process Monitoring Instruments. "Leak Detection and Repair (LDAR): A Comprehensive Introduction". AZoM. 28 April 2024. <https://www.azom.com/article.aspx?ArticleID=20136>.

  • Chicago

    Thermo Fisher Scientific – Environmental and Process Monitoring Instruments. "Leak Detection and Repair (LDAR): A Comprehensive Introduction". AZoM. https://www.azom.com/article.aspx?ArticleID=20136. (accessed April 28, 2024).

  • Harvard

    Thermo Fisher Scientific – Environmental and Process Monitoring Instruments. 2023. Leak Detection and Repair (LDAR): A Comprehensive Introduction. AZoM, viewed 28 April 2024, https://www.azom.com/article.aspx?ArticleID=20136.

Ask A Question

Do you have a question you'd like to ask regarding this article?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.