Thermal Analysis

Featured Equipment
The model AHT-12 thermal flux meter available from ITI is a sophisticated solid state, flat-plate transducer, which is designed for direct measurement of heat flow.
The Model HT-50 Thermal Flux Meter available from ITI is a solid state, flat-plate transducer, which is particularly designed for direct measurement of heat flow.
MKT 50 is a Millikelvin Thermometer which is designed for accurately measuring the temperature when used in combination with two highly precise platinium resistance thermometers.
ITI offers the series CR-100 thermal gradient microcalorimeters that are exclusively designed to offer a precise measurement of radioisotope heat release rates.
The Q600 provides simultaneous measurement of weight change (TGA) and true differential heat flow (DSC) on the same sample from ambient to 1,500 ˚C. It features a field-proven horizontal dual beam design with automatic beam growth compensation, and the ability to analyze two TGA samples simultaneously. DSC heat flow data is dynamically normalized using the instantaneous sample weight at any given temperature.
The TAM Air is widely used for studying the reaction kinetics of pure cement pastes as well as the temperature dependence of the reaction. TAM Air is an excellent tool for quality control in cement plants, for optimization of additives to give a cement a certain property, as well as a general research tool for the cement laboratory.
The Model C-3500 flame intensity calorimeter probe from ITI is used for measuring the overall heat flux, i.e. convection and radiation, in high temperature combustion of gases. This water-cooled instrument can be directly immersed in flame fronts.
The models A~E thermal flux meters available from ITI are advanced solid state, flat-plate transducers that are specifically designed to directly determine the heat flow.
Other Equipment
The LFA 467 HyperFlash has a very broad range available from -100°C to 500°C. With a single instrument setup, without swapping either the furnace or the detector, the LFA 467 HyperFlash can carry out measurements from -100°C to 500°C.
The CLA 5 is a new, improved version of the automatic flash and fire point testing device, CLA 4, and is specifically designed for viscous materials with a flash-point ranging from +79°C to +400°C, The device is used to identify the dangers of combustible materials in accordance to safety and shipping regulations.
The displacement transducer equipping the SETSYS Evolution TMA models is characterized by its robustness and high accuracy: it can detect dimension changes of as little as 0.01 micron.
Fibercraft™ low mass vacuum formed ceramic fiber heaters are a heating element and insulation together in one complete unit. These heaters are manufactured using high quality, high purity ceramic fiber with a low sodium inorganic binder. They are offered with maximum operating temperatures of 1100°C (2012°F) or 1200°C (2192°F).
APTAC 264 takes the testing of chemical reactivity a step forward by enabling the user to acquire much faster temperature and pressure rise data than did the earlier designs. The APTAC 264 can function as: High-performance closed-cell adiabatic calorimeter; High-temperature and high-pressure reaction calorimeter; Open test cell from which effluent can be discharged and analyzed for emergency relief system studies using the DIERS methodology of the American Institute of Chemical Engineers
The new STA 449 F1 Jupiter® combines unlimited configuration flexibility and unmatched performance in just one instrument.
The heart of a TGA is the balance cell. Our TGA instruments use the world’s best micro and ultra-micro balances. By using one of the three removable sensor types the TGA/DSC 1 simultaneously measures heat flow in addition to weight change. Thanks to its modular design, the TGA/DSC 1 is the ideal instrument for manual or automated operation in production and quality assurance through to research and development.
NETZSCH offers a new exchangeable calorimeter module for the MMC 274 Nexus particularly dedicated to coin cell battery studies.
The innovative DSC 214 Polyma is robust, easy to use and precise. The novel design of the instrument that includes everything required for successful DSC investigations, regardless of whether the user is a beginner or an experienced professional.
These semi rigid thermocouples can be used for a range of applications from simple temperature measurement to difficult environments. Insulated junctions are provided to prevent earth loops and it can be formed to shape to suit specific applications without an impairment in performance.
Orton offers DIL 2010 STD dilatometer that is typically used for dilatometry or Thermal Dilatometer Analysis (TDA).
Kipp & Zonen offers the CMP Series of pyranometers that are reliable, affordable, and can be used in a variety of applications. The CMP Series includes the SP Lite2, SMP3, SMP11, CMP 3, CM 4, CMP 6, CMP10, CMP 11, CMP 21, and CMP 22.
The Cosa 9600 is unmatched in terms of accuracy, speed of response and stability of measurement. The Cosa 9600TM is designed for applications requiring a continuous fast response measurement. The analyzer can be installed directly outdoors without any additional shelters.
The SMP11 smart pyranometer integrates sophisticated sensor technology with industry standard digital and analogue amplified outputs. Based on the proven CMP 11 technology the SMP11 adds Modbus® interface, improved response time and temperature corrected measurement data.
The IsoSORP® Manometric instrument is capable of determining gas adsorption and desorption of up to five samples using the static volumetric method.
Leco offers the advanced AF700 Ash Fusion Determinator that uses Windows-based software to automatically check the temperatures of ash cone deformation in mold powders, coke ash, and coal ash.
CMP 22 includes all the features of CMP 21 but uses very high quality domes for improved directional response, a wider spectral range and reduced thermal offsets.
IKA C 200 Calorimeter System allows you to accurately determine the Gross Calorific Value (GCV) of samples in either liquid or solid state. The digital display provides simple programming and method selection. Unit is suitable for low through-put laboratories, teaching and training, e.g. technical schools, universities, and for industrial laboratories with less need for analyses.
These semi rigid thermocouples are suitable for a range of applications from simple temperature measurement to more difficult environments. A 4-20 mA transmitter is included in the standard head so that the sensor can be extended with standard copper instrument cable into the loop system.
The DIL 806 optical dilatometer is an innovative and versatile instrument for thermal expansion and contraction measurements. Sample length is measured entirely without contact, making the instrument ideally suited for thin, irregularly shaped, and soft samples.
The Model 603 HDTM is the larger of the two models of DTUL/Vicat test equipment and can test simultaneously up to six different specimens with the help of an automated testing sequence that proceeds based on user defined control and configuration parameters.
The swaged mineral insulated thermocouple with pot seal includes an innovative fast response, inexpensive, high-strength solution to a number of challenging temperature measurements. Robust large diameter with a low thermal mass enables incredibly quick response.
TC Limited offers a broad range of hand-held thermocouple sensors for a wide range of applications.
The Discovery TGA features our industry-leading thermobalance, innovative IR-heated furnace, patented Hi-Res TGA, and an autosampler unmatched in flexibility and reliability.
TC Limited offers a broad range of hand-held thermocouple sensors for a range of applications. All sensors are supplied with a 1 m coiled lead while extended and a miniature fixed flat pin plug that makes it suitable for the company’s range of hand held indicators as well as most other proprietary indicator brands.
Thanks to its modular design, the DSC1 as part of the METTLER TOLEDO Thermal Analysis Excellence Line is the best choice for manual or automatic operation, from quality assurance and production through to research and development. The DSC utilizes an innovative patented DSC sensor with 120 thermocouples which guarantees unmatched sensitivity.
AC600 is a Semi-Automatic Isoperibol Calorimeter for Gross Calorific Content. The AC600 sets the standard for future calorimetry instruments. Its semi-automated operation, combined with the use of thermodynamic TruSpeed®, obtains a rapid analysis of calorific content and increased instrument throughput without sacrificing accuracy or instrument precision. A new, ergonomically designed, lightweight combustion vessel assures ease of operation while greatly reducing operator strain.
The SMP3 is a smart pyranometer with low maintenance and industry standard digital and analogue amplified outputs. The SMP3 is based on the proven CMP 3 technology, includes a Modbus® interface, improved response time and temperature corrected measurement data.
Thermal imaging cameras are used for research and development applications. The SC35/SC15 and SC5 packs FLIR systems are capable of performing thermal imaging.
Portable cameras are highly sensitive, and have advanced features. They have the capacity to generate a combination of infrared and visible spectrum images having high temperature measurement accuracy and quality.
These small semi rigid thermocouples are suitable for a number of demanding precision temperature measurement applications because of the size, response, displacement and ruggedness of the assembly.
These thermocouples with a standard round pin plug can be used for simple temperature measurements to more difficult environments. Insulated junctions are provided for prevention of earth loops and these can be formed to shape to suit specific applications without impacting performance.
The Discovery DSC provides unmatched precision, accuracy, industry-leading sensitivity and resolution.
These thermocouples are semi-rigid and can be used for a wide range of applications from simple temperature measurement to difficult environments.
The FLIR SC5000 series has high spatial resolution, accuracy and sensitivity. 320 x 256 or 640 x 512 pixels format Indium Antimonide (InSb) focal plane array is provided in the FLIR SC5000 series that has a frame rate of about 380 or 100 Hz.
The MILA-5000 series is designed to perform clean sample heating and ultra-fast heating and cooling operations, which are characteristics of the Infrared Gold Image Furnace RTA units.
The DIL805A/D is a special dilatometer used for the determination of the deformation parameter and for the creation of continuous cooling, TTT-, and DTTT- diagrams.
This range of type R, S and B thermocouples are suitable to be used in high temperature environments where standard sheath materials are not suitable because of inaccuracies due to contamination of the core conductors.
The flat film Pt100 elements are placed on a ceramic substrate and these laser trimmed Pt100 elements have a range of uses that include measuring the surface or air flow temperatures.
CMP10 is the secondary standard pyranometer with very good price-quality-performance ratio on the market. Based on the established CMP 11 technology, CMP10 extends this quality to applications where maintenance is difficult and/or forms a major part of the cost of ownership.
SP Lite2 has been designed for routine measurement of solar radiation. One can use SP Lite2 in all weather conditions. The solar energy received from the entire hemisphere is determined by the sensor.
The LTF-631 High Speed Dielectric Cure Monitor is designed for the study of rapidly reacting materials in Research and Development, Quality Assurance or Quality Control, and Production applications involving thermoset materials such as resins, composites, paints and coatings.
The FLIR X8000 sc/X6000 sc series thermal imaging cameras provide advanced connectivity and excellent thermal measurement performance. The FLIR X8400 sc produces thermal images of about 1280 x 1024 pixels for ensuring high measurement accuracy and providing smallest image details.
The Mobile-IR is an autonomous and robust mobile infrared spectrometer for identification of unknown substances.
The FLIR A305 sc-A325 sc and FLIR A645 sc-A655sc infrared cameras are used for maintaining the thermal efficiency of development project under constant control. These cameras reduce time-to-market and avoid occurrence of faults while designing.
These semi rigid thermocouples are suitable for a wide range of applications from simple temperature measurement to more difficult environments. Insulated junctions are provided for prevention of earth loops and can be formed to shape to suit specific applications without impacting performance.
DMA25 is a desktop DMA offering a high force range up to 25N and outstanding flexibility from glass transition determination to immersed tests, which makes it a powerful thermomechanical testing platform.
These small semi-rigid thermocouples are suited for a number of challenging precision temperature measurement applications because of the size, response, displacement and robustness of the assembly.
The multi-functional design of the DEA 288 Epsilon (including furnace or laboratory press) allows for the application of a great variety of different test conditions such as heat, cold, humidity or UV light.
The Q400 is the industry standard research grade thermomechanical analyzer (TMA, with unmatched flexibility in operating modes, test probes, and available signals.
The Benz TR 2200 temperature retraction tester determines the impact of low temperature on plastic, rubber and other elastomeric materials.
Portable cameras are capable of producing a combination of infrared and visible spectrum images with high temperature measurement accuracy and quality. They are highly sensitive, and have advanced features. They include laser pointer, contrast optimizer, and other advanced features.
The new DSC 404 F1 Pegasus®, High-Temperature Differential Scanning Calorimeter, is designed for the exact determination of specific heat of high-performance materials at high temperatures. The new concept of the DSC 404 F1 Pegasus® allows configuration for up to five different furnace types, easily interchangeable by the user, for a wide temperature range within -150°C...2400°C.
MMR's Variable Temperature Micro Probe Systems, VTMP, (or Low Temperature Micro Probe Systems, LTMP) allow the user to probe devices mounted on the cold stage of a micro refrigerator. Each manipulator allows the corresponding probe to be positioned anywhere on a 10 mm x 12 mm sample to a precision of 50 microns.
The 3D-DMA employs experimental techniques grounded in metals testing experience. Extensometers measure strain locally on axially loaded specimens, rather than relying on contact point displacement on flexing beams. The system concurrently measures dynamic Young's Modulus, E*, and viscoelastic Poisson's ratio, �*.
The new TMA incorporates true, high quality Swiss precision mechanics. Offering nanometer resolution, it can measure the very slightest dimensional changes in samples.
The thermoMETER CT laser is a high performance temperature sensor with laser spot marking. The thermoMETER CTlaser sensors are used in industry for precision measurement tasks. Both the laser beams mark the actual measuring spot for any distance.
Photon Control offers a range of highly accurate temperature system converters, that can be paired with Immersion, Contact, or Life Science probes for specific application requirements. A probe and a converter must be selected and each system comes with downloadable analyzing software.
TC Limited offers a broad portfolio of hand-held thermocouple sensors for a wide range of applications.
TC offers a broad portfolio of hand held thermocouple sensors for a range of applications.
To maximize sample throughput, the DIL 803/803L offers two-sample simultaneous operation in a horizontal dilatometer. The DIL803/803L can also be operated with an inert reference sample for differential measurement, reducing the influence of measurement system expansion and increasing measurement accuracy under dynamic temperature conditions.
TC Limited offers a broad range of hand-held thermocouple sensors for a large range of applications.
It is possible to simultaneously weigh two samples with the IsoSORP instruments. Along with determining the mass change of the sample material, a second inert sample can be weighed.
The Binder incubator BF115 with mechanical convection is suited for all gentle incubation applications, especially under full load and large batch throughputs. This incubator is has extremely low temperature variation and has rapid recovery times.
IST platinum temperature sensors provide solutions for extreme temperature applications. IST products are designed with the highest quality materials, allowing them to operate within a temperature range of -200°C to +1000°C. Standard DIN 60751 sensors are offered in class B (0.12%), class A (0.06%), 1/3 class B (0.04%), and higher accuracies upon request.
TA Instruments offers a range of instruments for measuring thermal diffusivity over a wide temperature range (-150 to 2800°C). Modular architecture makes the Discovery Flash platform perhaps the most flexible system of its kind. It allows the addition of other furnaces at a later date to grow with changing needs, and includes the multiple specimen testing option for all models, pioneered by our predecessor company, Anter Corporation.
The heart of the TMA 402 Hyperion® is a highly precise inductive displacement transducer (LVDT). This technology has stood the test of time; it is also used for dilatometers and allows measurement of even the smallest of length changes, into the nanometer range (digital resolution of 0.125 nm).
The NETZSCH LFA 457 MicroFlash® complies with the latest technology for modern laser flash systems. LFA 457 MicroFlash® allows measurements from -125°C to 1100°C using two different user-exchangeable furnaces. The innovative infrared sensor technology employed in the system enables measurement of the temperature increase on the back surface of the sample, even at temperatures of -125°C.
The smaller of the two models of DTUL/Vicat test equipment is the Model 303 HDTM and it can test three different specimens simultaneously, using an automated testing sequence that proceeds according to user defined control and configuration parameters.
With the TMA/SDTA840 you can measure dimensional changes of a sample as a function of temperature.
The TG 209 F1 Libra thermobalance allows you to measure mass change of materials as a function of temperature in the range 10-1100°C. The instrument has been designed for ease of use and to protect delicate components to ensure minimum down time.
Anton Paar’s ADU 5 high-precision atmospheric distillation unit is the perfect solution to perform accurate atmospheric distillation tests to distinguish the volatility of petrochemical products, such as ethanol-blended gasoline, biodiesel, and all standard fuels.
Instron offers the latest range of 3119-600 Series environmental chambers that has been specifically developed for usage with dual column table model testing systems.
Guarded Hot Plates are employed in the most demanding R&D and QA applications where faster instruments (such as guarded heat flow meters) do not suffice, or do not possess the broad operating range desired.
VITA technology adds high resolution nanoscale thermal characterization capabilities to Bruker's Dimension® Icon® AFM, Dimension Edge AFM, and MultiMode® 8 SPM.
The HP DSC 1 is a state-of-the-art high pressure DSC. This instrument allows you to measure samples under precisely defined atmospheres at overpressures of up to 10 MPa as a function of temperature and time.
Unitherm 1000 is a fully computerized dilatometer system designed to measure dimensional changes of a specimen brought about by changes in its thermal environment. Linear thermal expansion coefficient, annealing characteristics and other physical or chemical changes manifesting themselves in a change of linear dimension can be precisely determined.
The Model 603 HDTM and the Model 303 HDTM are the latest generation of Tinius Olsen’s digitally controlled Automatic Deflection Temperature/Vicat test equipment. The 603 HDTM is capable of testing up to six different specimens simultaneously, and the smaller 303 HDTM can test up to three specimens simultaneously, both with an automated testing sequence that proceeds according to user defined control and configuration parameters.
EKT-TR100 TR-Low Temperature Retraction Tester is designed in accordance with ASTM D1329, ISO 2921 with fully automatic and computerized controlling system.
NETZSCH’s Accelerating Rate Calorimeter 254 (ARC® 254) offers adiabatic calorimetry information in a safe, controlled laboratory setting.
The CMP 21 is a high performance research grade pyranometer, and is completely compliant with all ISO 9060:1990 Secondary Standard Instrument performance criteria.
The METTLER TOLEDO DMA/SDTA861e is the latest DMA introduced in the market. In comparison with conventional DMA instruments it offers new and unique performance benefits: A frequency range up to 1000 Hz for material behavior simulation and accurate determination of moduli through the presence of a dedicated force sensor.
The Complete Calorimeter for Hazards Screening and Vent Sizing
The ADP440+ is a single wavelength, high precision polarimeter that can be used in a range of applications and is particularly suitable for use in pharmaceutical laboratories where compliance with Pharmacopoeia is needed.
Anton Paar offers the MKT 50 Millikelvin Thermometer, which in tandem with two platinum resistance thermometers, calculates the temperature with a high degree of precision.
With Melting Point Meter M5000 from KRÜSS Optronic, powdery substances with a melting point up to 400 °C can be examined. A fan cooling allows fast measurements in every range of temperature. The display provides a clearly-arranged readout of all important measuring data.
The new MP90 Melting Point System has been optimized for completion of the most diverse tasks and the highest throughput.
The LT-451 Dielectric Cure Monitor is a versatile compact instrument developed for research and development, quality assurance or quality control and production applications that involve thermoset materials such as resins, composites, paints and coatings.
Are higher sample throughput, direct comparison of samples, and online calibration of expansion measurements important requirements for you? With the new dilatometer DIL 402 CD we handle these tasks perfectly with our unique, new instrument concept.
The Binder oven and chamber range covers all types of routine applications and also highly technical and specific tasks, taking pride in offering unique precision in both areas.
Harper pioneered the Microline concept based on the flexibility to change and modify for the needs of customers in research and development of advanced fiber processing techniques.
HFM 436 Lambda, the heat flow meter from NETZSCH, is designed for precise thermal conductivity testing of insulation materials.
The primary scope of TG-GC-MS coupling is to detect, separate and analyze organic components. It is also possible to use the coupled GC-MS for detailed gas analysis to further improve the temperature-programmed pyrolysis of organic materials, biomass, renewable solid fuels, carbonaceous materials, and polymers in the TG/STA. The volatile products emitted during combustion processes can be determined with high sensitivity and resolution at various oxygen content levels.
TC Limited offers a broad range of hand-held thermocouple sensors for a range of applications.
A new, universal range of Reaction Calorimeters for Safety Investigations and Scale-Up. All Calorimeters Calo 2310 eco, base and pro are suitable for Safety Investigations as well as Scale-Up Applications.
The Varicon sensor has been designed to be used in molds, presses, laminates or bulk material where a flexible, thin dielectric sensor is required. The Varicon sensor is quite thin and can be embedded in a sample or between the plies of a laminate and may be discarded after use.
The MMC 274 Nexus available from NETZSCH is a multiple module calorimeter and includes two parts: the base unit with built-in electronics and the exchangeable calorimeter module.
When it comes to determination of the linear thermal expansion in solids, liquids, powders and pastes as well as ceramic fibers, the DIL 402 C vacuum-tight pushrod dilatometer leaves no measurement problem unsolved.
The new DMA 242 E Artemis combines ease of handling with the user-friendly Proteus® measurement and evaluation software. This makes it fast and easy to characterize the dynamic-mechanical properties as a function of frequency, temperature and time.
The new FluoTemp GT-HT temperature converter integrates high consistency, reliability and improved diagnostics even when exposed to high temperature and electro-magnetic interference (EMI) environments.
The TMA 801 operates in a vertical orientation, making it ideal for the analysis of sintering, RCS (rate controlled sintering), viscoelastic behavior and the determination of softening temperatures. The linear motor generates a constant throughout the experiment, ensuring that contact is maintained with the sample regardless of dimension change.
The Instron® CEAST HV500 is the latest instrument design to perform HDT and VICAT tests at high temperatures, up to 500°C, making this instrument ideal for research and quality control applications as it is ensuring the capability to test the new generations of techno-polymers, characterized by their excellent properties at high temperature.
Orton dilatometers are designed to measure the dimensional changes of ceramics, glasses, metals, carbon composites, cermets, minerals, and polymers as a function of temperature.
The new Flash DSC 1 represents a quantum leap in Thermal Analysis and opens up new frontiers in the field of materials characterization.
A broad variety of handheld thermocouple sensors are offered from TC for a range of applications.
Orton offers the DIL 2016 STD dilatometer, which is often used for Thermal Dilatometer Analysis (TDA).
The PYRO Optical pyrometer temperature sensor for non contact high temperature measurement operates by allowing the operator to compare the intensity of light radiated from a target at visible. The PYRO Optical pyrometer can achieve temperature measurement accuracy to ± 0.5% of the temperature being observed. Small target sizes from 0.055" at distances of 3" to infinity can be achieved.
The new GHP 456 Titan® is the ideal tool for researchers and scientists in the field of insulation testing. Based on the well-known, standardized guarded hot plate technique (e.g. ISO 8302, ASTM C 177 or DIN EN 12667), the system features unrivalled performance over an unmatched temperature range.
The NETZSCH Photo-DSC 204 F1 Phoenix®, Differential Scanning Calorimeter, works in the temperature range from -100°C to 200°C. The instrument has a gas-tight measuring cell and the purge gas control is regulated by a mass flow controller (MFC). For our Photo-DSC 204 F1 Phoenix®, most standard industry or laboratory lamps for cationic or radically curing material systems can be used.
Preiser Scientific's new 6000 Series of Plastometer/Dilatometer controllers provide for great flexibility by allowing two tests to be run with only one controller.
Lambient Technologies offers the LTT-203 Process Controller, which provides an ideal solution for controlling the temperature of heating devices such as kilns, hot plates, ovens etc. The LTT-203 is compact and portable and accepts Type B, E, J, K, L, R, S, and T thermocouples. It does not require any assembly or set-up.
Kipp & Zonen supplies the SP Lite2 pyranometer, which is designed for routine measurement of solar radiation.
The DTC-300 measures thermal conductivity of a variety of materials, including polymers, ceramics, composites, glasses, rubbers, some metals, and other materials of low to medium thermal conductivity.
Thermal conductivity and thermal diffusivity are the most important thermophysical parameters for characterization of the thermal transport properties of a material or component. The TCT 426 thermal conductivity tester enables the use of all three of the methods described in easily interchangeable, pre-wired measuring frames.
CMP 11 makes use of the temperature compensated detector technology originally developed for the CMP 22 and is a step up in performance from the CMP 6. It is especially ideal for meteorological networks and the reduced response time of 1.66s (63%) meets the requirements for solar energy applications.
The expertise of Harper International in advanced thermal processing design helps them offer the latest fully integrated production lines for carbon nanotubes, carbon fiber and metal oxide materials.
TC Limited offers a broad range of hand-held thermocouple sensors for a range of applications.
These thermocouples are semi rigid and are suitable for applications from simple temperature measurements to more difficult environments.
The FLIR A305 sc - A325 sc and FLIR A645 sc - A655 sc infrared cameras are designed to keep the thermal efficiency of the development project under constant control. It prevents design faults in the making, ensures quality and cuts time-to-market.
Suitable for the widest range of routine thermal expansion measurements, the DIL 801 and DIL801L are horizontally configured single-sample dilatometers. The DIL 801 is designed for measurements under vacuum or inert gas while the DIL 801L is designed for measurements in air, making the DIL 801L ideally suited to measuring ceramic materials which are often processed in air.
The TSic™ product family consists of chip-integrated and calibrated temperature sensors with an integrated signal converter for analog or digital signal output. TSic™ offers measurement accuracy from ±0.5°C to far below ±0.1°C and also medium (0.1°C) to high (0.034°C, 0.004°C) signal resolution for optimal temperature control.
This thermocouple with IP67 miniature weatherproof head is an innovative, fast response, inexpensive, high-strength solution to challenging temperature measurement applications.
The Kipp & Zonen CM 4 High Temperature Pyranometer is a radiometer specially designed for determining solar or artificial light irradiance under the most extreme temperature conditions.
Thermogravimetric (TG) measurements are a proven method in physics, chemistry and materials science.
The FL-5000 is perhaps the most flexible system of its kind. It allows the selection of subsystems and options to assemble a configuration that best suits any application. Many of these elements are interchangeable or selectable as an addition at a later date to grow with changing needs.
These semi rigid thermocouples can be used for all applications ranging from simple temperature measurement to difficult environments.
The new Concavus pan available from NETZSCH has a slight concave bottom geometry that produces an accurately defined contact surface between the pan bottom, sample and sensor, and thus helps in improving the reproducibility of the measurement results.
Variable Temperature Options for Optical Systems is designed for Raman and fluorescence measurements to be made over a wide range of temperatures. The Dewar has three windows, two for the entrance and exit of the exciting beam and one at right angles to this for observing the Raman or fluorescence radiation.
UCAR metal-ceramic LT-l is a combination of a metal matrix, chromium, and a pure ceramic phase, aluminium oxide (alumina). It is composed 65% by volume of metallic phase and 35% by volume of ceramic phase. The material is slip cast, sintered, and then oxidised. Although the exact nature of the bond between the phases is not known, a physical-chemical bond may be formed through the sharing of oxygen by the chromium and the alumina. There is no evidence of wetting or solution.
We offer a wide range of hand held thermocouple sensors for a variety of applications.
The Thermcraft Duracraftâ„¢ DC-1300 design incorporates helically wound heavy gauge conventional wire or Kanthalâ„¢ APM powdered-metal wire. The DC-1300 is typically used in all high temperature processes including silicon nitride and HTO LPCVD, oxidation, anneal, and drive-in. Ideal for horizontal furnace retrofits.
The novel CB series offers optimal growth conditions for cell cultures. The anti plenum concept, the 180°C sterilization routine with the world's first sterilizable CO2 sensor and other unique BINDER technologies satisfy the highest requirements for best possible cell growth and maximum sample safety in the premium class of BINDER CO2 incubators.
The versatile Premium DSC 204 F1 Phoenix® fascinates with its unique concept: all essential operational components are integrated into the instrument and optional add-ons can be installed anytime on site.
A number of leading companies consider the RFM300+ series refractometers as the ultimate instrument to be installed in challenging factory environments and also as a primary quality control tool.
IST nickel temperature sensors provide solutions for precise temperature measurement applications and are a direct replacement for nickel-balco sensors. IST nickel temperature sensors operate within a temperature range of -60°C to +300°C.
MMR Technology offers micro miniature refrigerators, which are compact, cryogenic devices used in scientific applications. The refrigerators get their cooling power from the Joule-Thomson expansion of a high-pressure gas.
Thermal conductivity and thermal diffusivity are the most important thermophysical material parameters for characterizing the thermal transport properties of a material or component. The Laser Flash technique is currently the most widely accepted method for precise measurement of the thermal diffusivity and the LFA 427 is the number one instrument on the world market. High precision and reproducibility, short measurement times, variable sample holders and defined atmospheres are outstanding features of LFA measurements over the entire application range from -70°C to 2800°C.
The CMP 3 pyranometer is an instrument used to measure the solar irradiance. The thermopile sensor construction determines the solar energy received from the total solar spectrum and the complete hemisphere, 180° field of view.
This novel range of Type R, S and B thermocouples are suitable to be used in high temperature environments where standard sheath materials cannot be used because of inaccuracies caused by contaminating the core conductors.
The DIL 2012 STD dilatometer available from Orton is used for Thermal Dilatometer Analysis (TDA), also called as dilatometry.
Life Science professionals know that the thermodynamic driving forces of macro-molecular interactions are critical parameters for the design of effective biomedical and pharmaceutical treatments. Calorimetry has become the method of choice for characterizing the thermodynamic driving forces of critical molecular interactions and defining molecular stabilities.
The magnetic suspension balance from Rubotherm is at the heart of the company’s gravimetric product lines for weighing the sample material accurately.
The Ceramicomb-1” is designed for use in presses, molds or harsh environments where a rugged, reusable dielectric sensor is desired.
For highest measurement accuracy, the DIL 802/802L provides a truly differential measurement in a horizontal dilatometer. Measuring only the difference between the sample and the inert reference, the design of DIL802/802L negates the influence of measurement system expansion on the sample measurement.
MCR rheometers are capable of performing dynamic-mechanical thermal analysis (DMTA) of solids, fibers and films when used in combination of heating systems CTD 450 and CTD 600.
These Pt100 elements are ideal for applications that need temperature stability and high temperature shock resistance.
The BINDER FED Series heating chambers offer a very large capacity, and are adaptable to many different applications.
Various insulation types and configurations are available from Thermcraft to meet your specific requirements. Sizes and shapes available are almost endless, from flat boards and flexible blanket, all the way to complex CNC machined insulation shapes.