Zwick Scores Top Marks For Not Marking the Specimen With New Non Contact Extensometer

Zwick will be presenting the world’s most technically advanced non contact extensometer at the Control Exhibition in Germany (May 8. -11., 2007) and at testXpo, the 3rd Asian Forum for Materials Testing Shanghai ( May 15.-18., 2007

 

The Zwick Roell Group, building on its global success as a pioneer of non contact extensometers, has developed a new product which is set to revolutionize the measurement of strain.  Designed for both the measurement of Young’s Modulus and strain at specimen failure using only one device, the laserXtens makes no contact with the specimen under test and requires no specimen marking.

For research and development applications, the laserXtens brings major benefits due to its high resolution, accuracy and flexibility, whilst for production control especially using robot technology, the lack of specimen marking and operator involvement enables cost effective, safe, and easy to use operation.

The laserXtens meets class 1 of ISO 9513 (Class B2 of ASTM E83), and is designed to test materials in applications where a contact extensometer might be unsuitable due to its physical contact with the specimen or the whiplash experienced at specimen failure.  It also enables the testing of complex component shapes which would preclude the attachment of a traditional contact extensometer.

Due to their mechanical construction traditional clip-on extensometers have limited capability when testing small components.  The laserXtens can measure strain with a gage length as low as 1.5mm and at temperatures up to 1600 deg.C.

An optional transverse measuring system enables the measurement of r values and Poisson Ratio.

The features of the laserXtens are totally integrated into Zwick’s testXpert® software and make the total testing system very powerful and easy to use.

Zwick believes that the laserXtens extensometer will bring major benefits to the metal, composite, plastics, and rubber industry, and component testing in the Aerospace, Automotive, Medical, and the Building Industry.

 

This information has been sourced, reviewed and adapted from materials provided by ZwickRoell GmbH Co. KG

For more information on this source, please visit ZwickRoell GmbH Co. KG.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    ZwickRoell GmbH Co. KG. (2022, November 24). Zwick Scores Top Marks For Not Marking the Specimen With New Non Contact Extensometer. AZoM. Retrieved on April 26, 2024 from https://www.azom.com/article.aspx?ArticleID=3740.

  • MLA

    ZwickRoell GmbH Co. KG. "Zwick Scores Top Marks For Not Marking the Specimen With New Non Contact Extensometer". AZoM. 26 April 2024. <https://www.azom.com/article.aspx?ArticleID=3740>.

  • Chicago

    ZwickRoell GmbH Co. KG. "Zwick Scores Top Marks For Not Marking the Specimen With New Non Contact Extensometer". AZoM. https://www.azom.com/article.aspx?ArticleID=3740. (accessed April 26, 2024).

  • Harvard

    ZwickRoell GmbH Co. KG. 2022. Zwick Scores Top Marks For Not Marking the Specimen With New Non Contact Extensometer. AZoM, viewed 26 April 2024, https://www.azom.com/article.aspx?ArticleID=3740.

Ask A Question

Do you have a question you'd like to ask regarding this article?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.