Editorial Feature

Membrane Inlet Mass Spectrometry for Gas Analysis

Membrane Inlet Mass Spectrometry (MIMS) is a versatile technique for the direct analysis of gases that capitalizes on the unique ability of gases to diffuse through a membrane and enter a mass spectrometer for precise measurement. MIMS finds its niche in various scientific domains, with a particular emphasis on analyzing dissolved gases in liquids.

Gas Analysis, Membrane Inlet Mass Spectrometry, MIMS

Image Credit: S. Singha/Shutterstock.com

How does Membrane Inlet Mass Spectrometry Work?

Membrane Inlet Mass Spectrometry (MIMS) relies on the principles of mass spectrometry and the selective permeability of membranes that allow the passage of certain gases while excluding others, which is crucial in ensuring that only the target gases of interest reach the mass spectrometer. The process begins with the placement of the membrane inlet in the sample solution containing the dissolved gases. The membrane serves as a barrier, allowing gases to diffuse through it based on their individual permeabilities and enter the mass spectrometer for analysis.

The mass spectrometer then ionizes the incoming gases, separating them based on their mass-to-charge ratios, generating spectra that provide a detailed fingerprint of the gas composition, allowing for the identification and quantification of various gases present in the sample. The real-time nature of this analysis is a distinctive feature of MIMS, making it particularly useful for dynamic systems.

Why MIMS is Advantageous

MIMS offers several advantages over traditional gas analysis techniques, making it a preferred choice in specific applications. For instance, the direct diffusion of gases through the membrane allows for real-time analysis, making MIMS well-suited for monitoring dynamic processes, such as chemical reactions or biological fermentations.

Another notable advantage of MIMS is its high sensitivity since it can detect trace amounts of gases, even in complex matrices, owing to the membrane's selectivity and the sensitivity of mass spectrometry, making it an invaluable tool for studying dilute gases in various environmental and industrial settings. Moreover, MIMS enables in situ measurements without the need for sample extraction or pre-concentration, minimizing the risk of altering the sample composition and ensuring that the obtained data accurately reflects the in situ conditions. In applications where preserving the integrity of the sample is paramount, such as in marine environments, MIMS emerges as an ideal choice.

Applications of Membrane Inlet Mass Spectrometry

Oceanography

MIMS has found widespread use in the field of oceanography for studying dissolved gases in seawater. The ability to perform in situ measurements allows researchers to gain insights into gas exchange dynamics between the ocean and the atmosphere. This is crucial for understanding the carbon cycle, tracking nutrient cycling, and monitoring the impact of climate change on marine ecosystems. For instance, in a 2008 study, researchers successfully employed Membrane Inlet Mass Spectrometry (MIMS) to measure methane concentrations in aquatic environments. The use of the underwater mass spectrometer Inspectr200-200, coupled with a cool-trap for minimizing interferences, enabled precise measurements with a lowered detection limit of 16 nmol/L CH4. This facilitated detailed investigations of methane concentrations in coastal areas and lakes.

Fermentation Processes

In industrial settings, MIMS plays a pivotal role in monitoring fermentation processes. The real-time analysis of dissolved gases in fermentation broth provides critical information about the metabolic activity of microorganisms, optimizing process conditions, ensuring maximum product yield, and maintaining the efficiency of fermentation-based production processes in industries such as pharmaceuticals and biofuel production.

Gas Analysis in Analytical Chemistry

MIMS is a valuable tool in analytical chemistry for directly analyzing gases in various matrices. It has been utilized in studies ranging from analyzing headspace gases in food and beverages to measuring dissolved gases in chemical reactions. The versatility of MIMS makes it applicable to a wide range of analytical challenges.

Recent Development in MIMS

In a recent study, researchers have introduced a novel method, REduction-OXidation/MIMS (REOX/MIMS), for determining 15NO3 concentrations in isotope-enrichment experiments using Membrane Inlet Mass Spectrometry (MIMS). The method involves the reduction of NO3 to NH4+ by zinc powder and subsequent transformation of NH4+ to N2 gas. Compared to traditional techniques like elemental analyzer-isotope ratio mass spectrometry (EA-IRMS) or GC/MS, REOX/MIMS is more efficient, offering high accuracy (92.4%) and precision (1.49% average RSD). This upgraded OX/MIMS approach allows for the quantification of 15NO3 concentrations in small sample volumes (~15 mL) over a broad range (0.1–500 μM).

The study successfully applied REOX/MIMS to assess gross nitrification and NO3 immobilization rates in diverse ecosystems, demonstrating its convenience and accuracy in understanding nitrogen transformation rates in natural environments. The method's high-throughput capability and simplified sample processing make it a valuable tool for researchers studying nitrogen dynamics in various ecosystems.

Future Prospects

The future of Membrane Inlet Mass Spectrometry (MIMS) appears promising, with continuous advancements shaping its trajectory. The technique's real-time analysis, high sensitivity, and in situ capabilities position it as a cornerstone in various scientific realms. As technological innovations persist, MIMS is likely to witness further refinements, expanding its applications and enhancing efficiency.

The recent development of REduction-OXidation/MIMS (REOX/MIMS) exemplifies the ongoing evolution, showcasing improved accuracy and precision in isotope-enrichment experiments. This novel approach holds potential for broader adoption in diverse ecosystems, emphasizing MIMS as a crucial tool for unraveling intricate processes, from marine environments to industrial fermentations. As research endeavors push the boundaries, MIMS stands poised to play an increasingly pivotal role in unraveling the complexities of gas analysis across disciplines.

Revolutionizing Surface Chemistry: Mass Spectrometry in Material Engineering

References and Further Reading

Burlacot, A., Burlacot, F., Li-Beisson, Y., & Peltier, G. (2020). Membrane inlet mass spectrometry: a powerful tool for algal research. Frontiers in Plant Science. https://doi.org/10.3389/fpls.2020.01302

Douchi, D., Liang, F., Cano, M., Xiong, W., Wang, B., Maness, P. C., ... & Yu, J. (2019). Membrane-Inlet Mass Spectrometry enables a quantitative understanding of inorganic carbon uptake flux and carbon concentrating mechanisms in metabolically engineered cyanobacteria. Frontiers in Microbiology. https://doi.org/10.3389/fmicb.2019.01356

Hiden Analytical. (2021, December 17). Membrane Inlet Mass Spectrometry (MIMS): Using Mass Spectrometers to Detect Nitric Oxide. AZoM. Retrieved on November 16, 2023 from https://www.azom.com/article.aspx?ArticleID=15887.

Lin, X., Lu, K., Hardison, A. K., Liu, Z., Xu, X., Gao, D., ... & Gardner, W. S. (2021). Membrane inlet mass spectrometry method (REOX/MIMS) to measure 15N-nitrate in isotope-enrichment experiments. Ecological indicators. https://doi.org/10.1016/j.ecolind.2021.107639

Schlüter, M., & Gentz, T. (2008). Application of membrane inlet mass spectrometry for online and in situ analysis of methane in aquatic environments. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/j.jasms.2008.07.021

Disclaimer: The views expressed here are those of the author expressed in their private capacity and do not necessarily represent the views of AZoM.com Limited T/A AZoNetwork the owner and operator of this website. This disclaimer forms part of the Terms and conditions of use of this website.

Taha Khan

Written by

Taha Khan

Taha graduated from HITEC University Taxila with a Bachelors in Mechanical Engineering. During his studies, he worked on several research projects related to Mechanics of Materials, Machine Design, Heat and Mass Transfer, and Robotics. After graduating, Taha worked as a Research Executive for 2 years at an IT company (Immentia). He has also worked as a freelance content creator at Lancerhop. In the meantime, Taha did his NEBOSH IGC certification and expanded his career opportunities.  

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Khan, Taha. (2023, December 04). Membrane Inlet Mass Spectrometry for Gas Analysis. AZoM. Retrieved on April 27, 2024 from https://www.azom.com/article.aspx?ArticleID=23228.

  • MLA

    Khan, Taha. "Membrane Inlet Mass Spectrometry for Gas Analysis". AZoM. 27 April 2024. <https://www.azom.com/article.aspx?ArticleID=23228>.

  • Chicago

    Khan, Taha. "Membrane Inlet Mass Spectrometry for Gas Analysis". AZoM. https://www.azom.com/article.aspx?ArticleID=23228. (accessed April 27, 2024).

  • Harvard

    Khan, Taha. 2023. Membrane Inlet Mass Spectrometry for Gas Analysis. AZoM, viewed 27 April 2024, https://www.azom.com/article.aspx?ArticleID=23228.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this article?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.