Jolt of Electricity Can Help Detect Corrosion in Steel Bridge Cables

Across the United States, more than 200 million trips are taken daily across bridges rated structurally deficient or in need of significant maintenance and yearly inspection. One major culprit: corrosion of reinforcing steel.

Now, however, UB researchers believe they can detect corrosion before the damage becomes severe by sending a jolt of electricity between opposite ends of steel cables. An inconsistency in the charge would alert them that the cable is suffering from corrosion and the bridge is in danger of falling.

“The No. 1 priority of all civil engineers is the safety of the public,” says Tresor Mavinga, a UB senior civil engineering and mathematics major involved in the research. “Corrosion can affect any structure, not just bridges, and we don’t want that to happen. We need to be as accurate as possible to save money, time and lives.”

Led by Salvatore Salamone, assistant professor of civil engineering, Mavinga and Alireza Farhidzadeh, a civil engineering graduate student, embedded piezoelectric transducers — devices that convert a signal from one form of energy to another — onto each end of a wire.

They then fired one volt of electricity through the metal using ultrasonic-guided waves, which can travel a long distance with little loss in energy, while monitoring the charge received at each end. The experiment was repeated with the same wire after it was rusted with a saltwater mixture. Because the cables are corroded, most of the energy from the electrical charge will be lost during the transfer between transducers.

Since the sensors and transducers are permanently attached to the cable, engineers can test the wires remotely off-site.

The new method of testing could do away with time-consuming and expensive visual tests, which often rely on drilling through concrete to inspect the cables or spotting cracks in the concrete caused by increased stress on the weakened wires.

According to the Federal Highway Administration, corrosion problems have increased significantly over the past three decades and are likely to continue. The increase is in part due to the rising use of road de-icing salts, which are extremely corrosive to the protective films on metals.

Improved testing is a needed step toward improvement of American infrastructure.

U.S. bridges were graded a C-plus by the American Society of Civil Engineers in its 2013 Report Card for America’s Infrastructure. And of the more than 17,000 bridges in New York, 12.5 percent are structurally deficient and 27 percent are considered functionally obsolete.

The report adds that one out of nine of the nation’s bridges is structurally deficient and that more than 30 percent of bridges have exceeded their 50-year design life; the average age of the nation’s bridges is currently 42 years.

Source: http://www.buffalo.edu/

Tell Us What You Think

Do you have a review, update or anything you would like to add to this news story?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.