NanoDrop™ Ultra Microvolume Spectrophotometers and Fluorometers for Research and QC Applications

The Thermo Scientific NanoDrop Ultra Spectrophotometer and Fluorometers enable scientists to measure and evaluate nucleic acids and proteins with greater accuracy, speed, and dependability.

The next generation of microvolume detection is represented by the Thermo Scientific NanoDrop Ultra Spectrophotometers and Fluorometers. With sample quantities as little as 1.0 μL, these state-of-the-art devices provide remarkable sensitivity and accuracy for protein and nucleic acid detection.

Numerous disciplines, including genomics, proteomics, molecular biology, biotechnology, pharmaceutical, and life sciences research, can benefit from the NanoDrop Ultra's streamlined procedures. It offers unmatched accuracy, effectiveness, and dependability in a small package.

With the Thermo Scientific NanoDrop Ultra Microvolume UV-Vis Spectrophotometers and Fluorometers, users can grasp sample quality like never before and prevent expensive setbacks in the process. Every instrument has cutting-edge Thermo Scientific Acclaro Sample Intelligence technology for enhanced measurement precision and contamination detection.

Before deciding to use samples in downstream applications, get full-spectral data by quantifying and qualifying DNA, RNA, and protein samples in a matter of seconds using just 1–2 μL. For further versatility, versions that work with cuvettes are also offered.

The NanoDrop Ultra spectrophotometers' large, high-resolution 10.1-inch touch screen interface and compact form make them ideal for users seeking convenience and flexibility.

With an enhanced algorithm, the optional Acclaro Pro software - compatible with the NanoDrop Ultra instruments - unlocks increased accuracy for highly concentrated samples. Compared to the popular NanoDrop 2000/2000c and NanoDrop One/OneC Spectrophotometers, this next-generation NanoDrop single channel instrument has better hardware and software features.

Acclaro Sample Intelligence Technology

Acclaro technology provides precise quantitative assessments while improving user comprehension of sample quality. Early contamination detection can save days of debugging and save downstream applications from failing.

  • Contaminant detection and analysis: Enables users to accurately identify, measure, and reduce contaminants by providing a thorough assessment of sample purity AND correcting sample absorbance. Researchers, scientists, and experts in disciplines including agriculture, plant biology, microbiology, and genetic engineering have access to plant and bacterial DNA and RNA differentiations
  • Sample integrity insight - sends real-time notifications when bubbles are found in the sample, which may otherwise result in erroneous readings
  • Reliable precision is ensured by the use of an embedded sensor and computerized image analysis

Tools to Aid in 21 CFR Part 11 Compliance

Optional Thermo Scientific SciVault 2 software installs on either the instrument or a companion PC and provides labs with capabilities to comply with US FDA 21 CFR Part 11.

  • Compliance made easy: SciVault 2 integrates into the NanoDrop Ultra software user interface to handle user accounts, digital signatures, and audit logs.
  • On-board options: Software can be executed directly on the local instrument using on-board user account management, or users can link the instrument to the domain and manage the Windows accounts.
  • Centralized solution: Installing SciVault 2 software on a central computer allows users to monitor audit logs and manage permissions for several NanoDrop Ultra equipment located in various laboratories.

Streamlined Workflow

  • Completely integrated qPCR recipe calculator: let the software do the math for the user by adding the preferred kit or using the built-in library. Depending on the concentration of the sample, the qPCR recipe calculator recommends how to set up the reaction.
  • Auto-Measure and Auto-Blank features: Instantaneous measurements that take place when the pedestal arm is down can simplify multi-sample processing. One tap on the screen can activate or deactivate these features.

Advanced Connectivity for Data Storage, Printing and Sharing

  • Export to the cloud: Export data straight to well-known cloud storage platforms like Thermo Fisher Connect, Google Drive, and Microsoft OneDrive.
  • Direct LIMS integration: Send data directly into the LIMS with the assistance of an integrated RESTful API.
  • Easy data-to-printer options: Use Wi-Fi, Ethernet, or a USB printer to print the results straight from the NanoDrop Ultra device; use the Nanodrop Ultra PC Control software to print exported data from the PC.
  • Data User’s Way: Before exporting the data file, make sure it satisfies any downstream requirements by customizing and previewing its contents.

Accuracy Beyond Expectations with the Acclaro Pro Software

New versions of the most widely used measurement applications that are unlocked from the factory are included in this optional software package, which offers ±5 % error over the absorbance dynamic range.

  • Accurate high concentration measurements: Absorbance measurements within 5 % error up to 550 Abs (10 mm equivalent) up to 400 mg/mL IgG or 18,000 ng/μL
  • Quick dilution-free process: Take three measurements on the pedestal in two minutes with this quick, dilution-free method
  • Improved calibration: Bundled purchases receive an extra calibration from the manufacturer to ensure the instrument is calibrated for outstanding accuracy in Acclaro Pro applications

Source: Thermo Fisher Scientific

. .
Certifications/Compliance All NanoDrop instruments are approved to CE and UL/CSA.
Compatibility DYMO 550 Turbo printer, Bluetooth keyboard, mouse and barcode reader
Concentration dsDNA: Pedestal: 27,500 ng/μL BSA (IgG): Pedestal: 820 (400) mg/mL
Connections 2x USB-A Ports, 1x USB-C Port, Ethernet, Bluetooth, Wi-Fi
Detection Range dsDNA: Pedestal: 1.0 ng/μL, Cuvette: 0.2 ng/μL, BSA (IgG): Pedestal: 0.03 (0.015) mg/mL, Cuvette: 0.006 (0.003) mg/mL
Dimensions (L x W x H) 12.6 x 7.1 x 11.0 in (32 x 18 x 28 cm)
For Use With (Application) Nucleic Acid A260, A260/A280, A260/A230 and Labeled Nucleic Acids, Oligos;, Protein A280 and A205, Protein Pierce 660, Protein Bradford, Protein BCA, Protein Lowry, Labeled Proteins, OD600, UV-Vis, and Custom Methods, Acclaro Pro Applications
Includes ND Ultra Microvolume Spec
Keypad Built-in touchscreen
Measurement Time Standard: ≤7 sec Acclaro Pro: ≤30 sec
Pathlength 0.030 to 1.0 mm (auto-ranging)
Photometric Accuracy 3 % at 0.97 A, 302 nm, (Absorbance expressed at Abs/mm at 25 °C)
Photometric Range 10 mm equivalent: Pedestal: 0-550 A, Cuvette: 0-1.5 A
Power Consumption Operating: 15 W; Standby: 7 W
Processor Custom Linux
Repeatability Typical: 0.002 A (1.0 mm path) or 1 %CV, whichever is greater (SD of 10 individual measurements at 0.97 A)
Sample Volume (Metric) Min 1 μL
System Requirements Windows 10 or Windows 11
Warranty 2 Years
Wavelength Accuracy ±1 nm
Weight (English) Approximately 9.0 Ib.
Weight (Metric) 4.1 kg
Detector Type 2048-element CMOS Linear Image Sensor
Display 10 in. High Definition Color Display
Languages Chinese, English, French, German, Japanese, Spanish, Polish, Italian, Korean
Light Source Xenon Flash
Product Line NanoDrop
Spectral Bandwidth 1.8 nm
Voltage 12 VDC
Wavelength Range 190 to 850 nm
Unit Size Each

Other Equipment by this Supplier

Other Equipment

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.