High pressure can affect all chemical reactions and physical changes where there is a volume change. For quality control, process development or material testing, there is usually no alternative to DSC measurements under pressure.
- Shorter analysis time — reactions are expedited by higher temperatures and pressures
- Better interpretation — effects can be isolated by suppressing vaporization
- Measurements under process conditions — practical reaction environments can be simulated
![Sensor](https://d12oja0ew7x0i8.cloudfront.net/images/equipments/EquipmentImage_7945_16243424252683863.jpg)
Sensor. Image Credit: Mettler-Toledo International Inc.
![HP DSC-Microscopy.](https://d12oja0ew7x0i8.cloudfront.net/images/equipments/EquipmentImage_7945_16243424368454071.jpg)
HP DSC-Microscopy. Image Credit: Mettler-Toledo International Inc.
![HP DSC- Chemiluminescence.](https://d12oja0ew7x0i8.cloudfront.net/images/equipments/EquipmentImage_7945_16243424476195707.jpg)
HP DSC- Chemiluminescence. Image Credit: Mettler-Toledo International Inc.
![PC 10.](https://d12oja0ew7x0i8.cloudfront.net/images/equipments/EquipmentImage_7945_16243424549816526.jpg)
PC 10. Image Credit: Mettler-Toledo International Inc.
Specifications
HP DSC 2+ — High-Pressure Differential Scanning Calorimeter
Source: Mettler-Toledo International Inc.
. |
. |
Temperature range |
RT ... 500 °C / 700 °C |
Heating rate |
0.1…50 K/min |
Pressure range |
0 … 10 MPa (overpressure) |
Gas flow |
freely selectable, accurate control of purge gas flow rates and total pressure with external controller |
Atmospheres |
Measurements under different atmospheres: inert, oxidizing, reducing, reactive, e.g. nitrogen, oxygen, hydrogen, methyl bromide, ethylene, propylene, carbon dioxide, etc. There are certain restrictions for combustible and toxic gases |
Trade Name |
DSC |
Innovative Technology
Features and Benefits of the HP DSC 2+
Shorter analysis times — higher temperature and pressure expedite reactions
![HP DSC 2+ — A High-Pressure Differential Scanning Calorimeter from Mettler-Toledo](https://d12oja0ew7x0i8.cloudfront.net/images/equipments/EquipmentImage_7945_16243424599898730.jpg)
Image Credit: Mettler-Toledo International Inc.
Measurements under process conditions — practical reaction environments can be simulated.
![HP DSC 2+ — A High-Pressure Differential Scanning Calorimeter from Mettler-Toledo](https://d12oja0ew7x0i8.cloudfront.net/images/equipments/EquipmentImage_7945_16243424656474939.jpg)
Image Credit: Mettler-Toledo International Inc.
Better interpretation — effects can be isolated by suppressing vaporization.
![HP DSC 2+ — A High-Pressure Differential Scanning Calorimeter from Mettler-Toledo](https://d12oja0ew7x0i8.cloudfront.net/images/equipments/EquipmentImage_7945_16243424712229715.jpg)
Image Credit: Mettler-Toledo International Inc.
Higher gas concentrations — the reaction rate of heterogeneous reactions with gases is increased.
![HP DSC 2+ — A High-Pressure Differential Scanning Calorimeter from Mettler-Toledo](https://d12oja0ew7x0i8.cloudfront.net/images/equipments/EquipmentImage_7945_16243424768067647.jpg)
Image Credit: Mettler-Toledo International Inc.
Measurements under unique atmospheres — oxidative, oxygen-free conditions or measurements with combustible or poisonous gases can be made.
![HP DSC 2+ — A High-Pressure Differential Scanning Calorimeter from Mettler-Toledo](https://d12oja0ew7x0i8.cloudfront.net/images/equipments/EquipmentImage_7945_16243424826939196.jpg)
Image Credit: Mettler-Toledo International Inc.
Rugged sensor with high resolution and excellent sensitivity — very weak effects and exceptional temperature resolution of close-lying effects can be measured.
![HP DSC 2+ — A High-Pressure Differential Scanning Calorimeter from Mettler-Toledo](https://d12oja0ew7x0i8.cloudfront.net/images/equipments/EquipmentImage_7945_16243424870617806.jpg)
Image Credit: Mettler-Toledo International Inc.