The Professional VA series consists of compact, multifunctional analyzers designed for voltammetric trace analysis of metal ions and other substances, as well as for the determination of organic additives in electroplating baths using Cyclic Voltammetric Stripping.

  • Compact design for efficient use of bench space
  • Wide range of current measurement modes and calibration techniques to support diverse applications
  • Interchangeable measuring head for quick and simple transitions between methods
  • Modular configuration for system customization
  • Options for manual, semi-automated, and fully automated operation to match specific requirements
  • Advanced viva software for complete system control

Benefits

One System – Many Applications

The Professional VA systems cover the full range of voltammetric and polarographic analysis and can be used for applications such as:

  • Trace determination of metals, including cadmium, lead, nickel, cobalt, and iron in seawater, salts, and high-purity chemicals
  • Analysis of various transition metal ions in water samples
  • Additives and impurities in electroplating solutions
  • Determination of copper and iron in boiler feed water
  • Measurement of ultra-trace metal species in seawater
  • Organic additives in plating solutions with Cyclic Voltammetric Stripping (CVS)

The compact design of the Professional VA helps conserve valuable bench space. When multiple applications are required, the interchangeable measuring head enables quick and easy switching between methods, allowing analysis to continue without interruption.

Highly Sensitive Trace Metal Determinations

The following detection limits apply when a Multi-Mode Electrode is used:

Source: Metrohm USA Inc.

     
Antimony SbIII/SbV 200 ppt
Arsenic AsIII/AsV 100 ppt
Bismuth Bi 50 ppt
Lead Pb 50 ppt
Cadmium Cd 50 ppt
Chromium CrIII/CrVI 25 ppt
Cobalt Co 50 ppt
Copper Cu 50 ppt
Iron FeII/FeIII 50 ppt
Molybdenum Mo 50 ppt
Mercury Hg 100 ppt
Nickel Ni 50 ppt
Platinum Pt 0.1 ppt
Rhodium Rh 0.1 ppt
Selenium SeIV/SeVI 300 ppt
Thallium Tl 50 ppt
Uranium U 25 ppt
Tungsten W 200 ppt
Zinc Zn 50 ppt

Download the Brochure for More Information

Higher Throughput with Automation

The Professional VA can be customized with automation and liquid-handling modules to reduce manual workload while improving accuracy and reproducibility.

For example, Dosinos can be used to manage reagent and sample additions, pump stations can handle automatic rinsing, and a sample processor can enable fully automated analyses, delivering highly precise and reproducible results without operator intervention.

The Flexible Benchtop VA

Image Credit: Metrohm USA Inc.

Full System Control with Viva

The Professional VA and all connected modules are operated through the user-friendly and powerful viva software. With viva, methods can be adapted and edited to fully match specific application requirements.

The viva database stores all determinations together with the associated data, such as curves and results. Information is presented clearly in a practical list, and individual determinations can be opened with a single click. Built-in sorting, searching, and filtering functions make it quick and easy to locate specific data. Recorded results can also be reprocessed, for example, to perform retroactive recalibration using a newly measured standard solution.

The Flexible Benchtop VA

Image Credit: Metrohm USA Inc.

Systems

884 Professional VA

The 884 Professional VA is the universal entry-level instrument in the Professional VA/CVS series. When used in combination with a compatible measuring head and electrode set, it enables reliable trace analysis determinations.

The Flexible Benchtop VA

Image Credit: Metrohm USA Inc.

884 Professional VA Manual for Multi-Mode Electrode (MME)

The 884 Professional VA manual for the Multi-Mode Electrode (MME) is the entry-level instrument for high-end trace analysis using voltammetry and polarography with the Multi-Mode Electrode Pro, the scTRACE Gold, or the Bismuth electrode.

884 Professional VA Manual for CVS

The 884 Professional VA manual for CVS applications is the entry-level instrument for high-end determination of organic additives in electroplating baths using Cyclic Voltammetric Stripping (CVS), Cyclic Pulse Voltammetric Stripping (CPVS), and chronopotentiometry (CP), as well as for voltammetric heavy metal determinations with rotating disk electrodes.

The Flexible Benchtop VA

Image Credit: Metrohm USA Inc.

884 Professional VA Semiautomated für Multi-Mode Electrode (MME) with 2 Dosinos

The 884 Professional VA semiautomated for Multi-Mode Electrode (MME) is a convenient high-end routine analyzer for trace determinations using voltammetry and polarography with the Multi-Mode Electrode pro or the scTRACE Gold.

The Flexible Benchtop VA

Image Credit: Metrohm USA Inc.

884 Professional VA Fully Automated for VA

The automated analysis system enables high-performance and flexible trace determinations using voltammetry and polarography with the Multi-Mode Electrode pro or the scTRACE Gold.

The Flexible Benchtop VA

Image Credit: Metrohm USA Inc.

884 Professional VA Fully Automated for the Determination of Antioxidants

Automated analysis system for the voltammetric determination of antioxidants in lubricants, featuring automatic sample preparation with a sample changer.

The Flexible Benchtop VA

Image Credit: Metrohm USA Inc.

Download the Brochure for More Information

Options and Upgrades

Automation

Increase the Sample Throughput

The Professional VA system can be expanded with a range of automation modules to improve throughput, accuracy, and reliability of analyses:

  • Dosinos for automatic addition of reagents and samples
  • Sample processors enabling fully automated analysis of up to 56 samples in a single run
  • Pump stations for automatic rinsing of the measuring vessel
  • Level sensors to issue alerts when waste containers are full and to prevent overflow

Sample Preparation

Quick and Effective Sample Preparation

Organic contamination in a sample can interfere with the voltammetric analysis of trace levels of heavy metals. The 909 UV Digester rapidly and effectively decomposes organic molecules through UV photolysis (in accordance with DIN 38406, Parts 16 and 17), ensuring reliable determinations.

Software

User-Friendly Software

The Professional VA are controlled with viva software.

Benefits include:

  • Methods can be adapted to specific laboratory requirements
  • All information can be managed within the database
  • All relevant parameters can be configured as needed
  • Data can be evaluated, and user-specific results can be generated
  • Customized reports can be created
  • Specific user rights can be defined to ensure laboratory security
  • Method settings can be automatically adjusted according to sample properties

Other Equipment by this Supplier

Other Equipment

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.